Innovative technology and friendly use meeting all you requirements: simplicity, reliability, accuracy and competition. Today’s laboratory environment demands an expert system with an economic advantage. The revolution design make FULLY a compact and completed analyser. Your laboratory will become more advanced. The clinical chemistry system FULLY is uniquely designed to answer the real needs of laboratories: low acquisition and operating costs, simple and flexible use, minimum maintenance. |
![]() |
| REAGENT TRY | The particular design of the reagent bottle have been developed in order to avoid reagent losse - 20 position reagent tray to miximize the number of test/sample at a time - Flexibility to run both single and two reagent chemistries - Open system that enables the programming of an unlimited number of techniques |
![]() |
|
|---|---|---|---|
| SAMPLE AND REACTION TRY | The common shape of reaction wells and cups could be easily found in the local market - Programmable washing cycles between samples and tests for minimizing carry-over - Analysis of up to 54 samples at a time for walkaway convenience - Auto-rerun with pre-diluition |
![]() |
|
| WORKING OVERVIEW | Proven and high technique will assure accurate measuring system and easy maintenance - 18 ul flow cell volume for economical running costs - Auto-level sensing - Built in high performance PC computer - Peltier controlled flow cell temperature - Washing and Waste tanks level sensors |
![]() |
|
Biochemical Systems International Srl reserves the right to change specifications without prior notice.
| Main Menù | ![]() |
|---|
| Sample and Reagent Location | ![]() |
| Results Graph | ![]() |
Software Improvements for FULLY and FULLY SMART
New features allowed with version 1.11A.
Release date: 15th January 2007
- Enabled Walk Away/Skip capability for reagents, samples and wells found empty
- Enabled Autoresuming option on errors (NOTE: PID 6 firmware version should be 1.15 or more or 2.02 or more)
- Enabled modification of K-factor or standard values in method editor without supervisor password
- Allowed customization of printing layout for each module
- Service: enabled button to move down the plunger to make syringe disassembling easier
- Improved handling of filters warning window
- Enabled printing feature for Multistandard calibration curve.
- Improved printing feature for some buttons
- Improved status monitor
Software Improvements for FULLY VET
New features allowed with version 1.11A
Release date: 15th January 2007
- Enabled Walk Away/Skip capability for reagents, samples and wells found empty
- Enabled Autoresuming option on errors (NOTE: PID 6 firmware version should be 1.15 or more or 2.02 or more)
- Service: enabled button to move down the plunger to make syringe disassembling easier
- Improved status monitor
Biochemical Systems International Srl reserves the right to change specifications without prior notice.
| MEASURING SYSTEM | |
|---|---|
| Operating mode | Absorbance, End-Point, Fixed Time, Kinetic, Multistandard |
| Throughput | Up to 100 tests/hour |
| Light source | Halogen lamp 12V 20W |
| Spectral Range | 320-690 nm |
| Filter Wavelength | 340, 405, 492, 505, 546, 578, 630 nm, one free position |
| Measuring Range | From –0.200 to 2.500 O.D. |
| Flow Cell | 18 µl |
| Incubation temperature | 37°C ± 0.2°C |
| Minimum Reading volume | 350 µl |
| Typical Reading volume | 500 µl |
| SAMPLE HANDLING | |
| Sample number | 54 positions including samples, calibrators and controls/tray |
| Sample container | Cup (1.2 ml) |
| Sample volume | 2-200µl (1µl steps) |
| Automatic dilution | Pre and post dilution ration: 1:2 – 1:20 |
| REAGENT HANDLING | |
| Reagent tray | 20 bottles + 1 bottle for diluent |
| Reagent bottle | 45 ml |
| Reagent volume | Reagent 1 volume range: 30 to 1000 µl (1µl steps) Reagent 2 volume range: 0 to 1000 µl (1µl steps) |
| Liquid detection | Sensor |
| Reagent warming | Pre-heated ARM |
| Reagent identification | Position ID |
| Tray exchange | Possible with reagent bottles |
| REACTION | |
| Number of wells | 144 wells (12 wells x 12 strips) |
| Well volume | 1 ml |
| Well temperature | 37 °C; ± 2 °C |
| DILUTER | |
| Syringe | 1000 µl, 1 µl steps |
| Accuracy | ± 1% at 5 µl |
| COMPUTER | |
| Computer | Built-in |
| Computer description | Intel ® Processor, 20 GB HD, 128 MB RAM |
| Operating system | Microsoft Windows ® |
| Computer description | Intel ® Processor, 20 GB HD, 128 MB RAM |
| Display | TFT 12", 800X600 |
| Network adapter | Built-in |
| Printer | Built-in thermal printer, 120 mm |
| Output | RS232, LPT |
| Drive | CD ROM, Floppy disk 3.5’’ 1.44 Mbytes |
| GENERAL | |
| Power Supply | AC115-230V 50-60Hz full range |
| Dimensions | 720 (W) x 680 (D) x 750 (H) open or 530 (H) close mm |
| Weight | 55 kg |
Biochemical Systems International Srl reserves the right to change specifications without prior notice.
Each FULLY analyser is shipped with a StartUp Kit composed by the following items
| CODE | DESCRIPTION | QUANTITY |
|---|---|---|
| 300206/S | Sample Tray | 2 |
| 300207/S | Reagents Tray | 2 |
| 591007 | Reagents bottles | 40 |
| 591010 | Cup for reagent bottles | 40 |
| Labels for reagent bottles rolls | 2 | |
| 592004 | Reaction Wells | 45 |
| 592003 | Sample Cups | 500 |
| 592006 | KODAK cups | 20 |
| 591009/S1-S2 | 500ml bottles (Wash-Waste) | 2 |
| 400094 | Wasting tube (1 m) | 1 |
| Triton solution 15% 1:100 (500 ml) | 1 | |
| 129007 | Needle cleaning kit | 1 |
| Enlarging tubes pin | 1 | |
| 080027 | Spare fuses (5A, fast) | 2 |
| 132031 | Power cable | 1 |
| 170020/C1 | 20W 12V Lamp | 1 |
| 190418 | FULLY thermic printing paper rolls | 2 | User manual | 1 |
| 121417_2 | Washing well for needles | 1 |
| Software Cd-rom | 1 | |
| 610058 | User manual | 1 |
| 180189 | PC Keyboard | 1 |
| 180190 | Mouse | 1 |
| 300205 | Separated little part of the cover | 1 |
| Release protocol | 1 | |
| Warranty sheet | 1 | |
| Unpacking sheet | 1 | |
Biochemical Systems International Srl reserves the right to change specifications without prior notice.